Communication PROFIBUS DP/PROFINET IO

10.1 Communications according to PROFIdrive

Drive Functions

388

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

Bit

Meaning

Remarks

BICO

Note:

The bidirectional digital inputs/outputs (DI/DO) can be connected as either an input or an output (see also receive signal

A_DIGITAL).

MT_ZSW

Status word for the "central probe" function.

Table 10-26 Description of MT_ZSW (status word for the "central probe" function)

Bit

Meaning

Remarks

BICO

0

Digital input probe 1

1

Digital input probe 2

2

Digital input probe 3

3

Digital input probe 4

4

Digital input probe 5

5

Digital input probe 6

Display of digital inputs

For telegram 392, in addition, probes 3 and 6

6...7 Reserved

8

Sub-sampling probe 1

9

Sub-sampling probe 2

8

Sub-sampling probe 3

9

Sub-sampling probe 4

8

Sub-sampling probe 5

9

Sub-sampling probe 6

Not yet carried out.
For telegram 392, in addition, probes 3 and 6

10...

15

Reserved

CO: r0688

MTn_ZS_F and MTn_ZS_S

Display of the measuring time determined
The measuring time is specified as a 16-bit value with a resolution of 0.25 μs.

Features of the central probe

● The time stamps from probes in more than one drive can be transferred simultaneously in

a single telegram.

● The time in the controller and drive unit is synchronized via the CU_STW and the

CU_ZSW.

Note: The controller must support time synchronization!

● A higher-level controller can then use the time stamp to determine the actual position

value of more than one drive.

● The system outputs a message if the measuring time determination function in the probe

is already in use (see also p0488, p0489, and p0580).