Servo control

3.7 Current setpoint filter

Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

83

Table 3-7

Example of general 2nd order filter

STARTER filter parameters

Amplitude log frequency curve

Phase frequency curve

Numerator frequency f

Z

= 500 Hz

Numerator damping D

Z

= 0.02 dB

Denominator frequency f

N

= 900 Hz

Denominator damping D

N

= 0.15 dB

I

1

+]

I

=

 +]

Parameterization

The "current setpoint filter" parameter screen is selected via the following icon in the toolbar

of the STARTER commissioning tool:

Figure 3-13 STARTER icon for "current setpoint filter"

Function diagrams (see SINAMICS S List Manual)

● 5710 Current setpoint filters

Overview of key parameters (see SINAMICS S List Manual)

● p1656 Activates current setpoint filter
● p1657 Current setpoint filter 1 type
● p1658 Current setpoint filter 1 denominator natural frequency
● p1659 Current setpoint filter 1 denominator damping
● p1660 Current setpoint filter 1 numerator natural frequency
● p1661Current setpoint filter 1 numerator damping
● ...
● p1676 Current setpoint filter 4 numerator damping
● p1699 Filter data transfer