Basic information about the drive system
12
12.1
Parameter
Parameter types
The following adjustable and display parameters are available:
● Adjustable parameters (write/read)
These parameters have a direct impact on the behavior of a function.
Example: Ramp-up and ramp-down time of a ramp function generator
● Display parameters (read only)
These parameters are used to display internal variables.
Example: Current motor current
%,&2LQSXW
UHDGZULWHS
UHDGU
3DUDPHWHU
%,&2RXWSXW
6WDQGDUGUHDG
SDUDPHWHU
6WDQGDUGZULWHUHDG
SDUDPHWHU
Figure 12-1 Parameter types
All these drive parameters can be read and changed via PROFIBUS using the mechanisms
defined in the PROFIdrive profile.
Parameter categories
The parameters of the individual drive objects are categorized into data sets as follows:
● Data-set-independent parameters
These parameters exist only once per drive object.
● Data-set-dependent parameters
These parameters can exist several times for each drive object and can be addressed via
the parameter index for reading and writing. A distinction is made between various types
of data set:
– CDS: Command Data Set
By parameterizing several command data sets and switching between them, the drive
can be operated with different pre-configured signal sources.