Extended setpoint channel

2.9 Ramp-function generator

Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

63

:LWKWUDFNLQJ

:LWKRXWWUDFNLQJ

6SHHGDFWXDOYDOXH

6SHHGVHWSRLQW

6SHHGDFWXDOYDOXH

2XWSXWRI
UDPSIFWJHQHUDWRU

6SHHGVHWSRLQW

2XWSXWRI
UDPSIFWJHQHUDWRU

S

Q

W

W

W

W

Q

Figure 2-11 Ramp function generator tracking

Without ramp function generator tracking

● p1145 = 0
● Drive accelerates until t2 although setpoint < actual value

With ramp function generator tracking

● At p1145 > 1 (values between 0 and 1 are not applicable), ramp function generator

tracking is activated when the torque limit is approached. The ramp function generator

output thereby only exceeds the actual speed value by a deviation value that can be

defined in p1145.

● t1 and t2 almost identical

Function diagrams (see SINAMICS S List Manual)

● 1550 Setpoint channel
● 3060 Simple ramp function generator
● 3070 Extended ramp function generator
● 3080 Ramp function generator selection, status word, tracking

Signal overview (see SINAMICS S List Manual)

● Control signal STW1.2 OFF3
● Control signal STW1.4 Enable ramp function generator
● Control signal STW1.5 Start/stop ramp function generator
● Control signal STW1.6 Enable setpoint
● Control signal STW2.1 Bypass ramp function generator