Communication PROFIBUS DP/PROFINET IO

10.1 Communications according to PROFIdrive

Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

397

Error

value

Meaning

Comment

Additional

info

0x15

Response too long

The length of the present response exceeds the maximum

transfer length.

–

0x16

Illegal parameter address

Impermissible or unsupported value for attribute, number

of elements, parameter number, subindex or a

combination of these.

–

0x17

Illegal format

Write request: illegal or unsupported parameter data

format

–

0x18

No. of values inconsistent

Write request: a mismatch exists between the number of

values in the parameter data and the number of elements

in the parameter address.

–

0x19

Drive object does not exist

You have attempted to access a drive object that does not

exist.

–

0x65

Presently deactivated.

You have tried to access a parameter that, although

available, is currently inactive (e.g. n control set and

access to parameter from V/f control).

–

0x6B

Parameter %s [%s]: no write access

for the enabled controller

–

–

0x6C

Parameter %s [%s]: unit unknown

–

–

0x6D

Parameter %s [%s]: Write access

only in the commissioning state,

encoder (p0010 = 4).

–

–

0x6E

Parameter %s [%s]: Write access

only in the commissioning state,

motor (p0010 = 3).

–

–

0x6F

Parameter %s [%s]: Write access

only in the commissioning state,

power unit (p0010 = 2).

–

–

0x70

Parameter %s [%s]: Write access

only in the quick commissioning

mode (p0010 = 1).

–

–

0x71

Parameter %s [%s]: Write access

only in the ready mode (p0010 = 0).

–

–

0x72

Parameter %s [%s]: Write access

only in the commissioning state,

parameter reset (p0010 = 30).

–

–

0x73

Parameter %s [%s]: Write access

only in the commissioning state,

Safety (p0010 = 95).

–

–

0x74

Parameter %s [%s]: Write access

only in the commissioning state, tech.

application/units (p0010 = 5).

–

–

0x75

Parameter %s [%s]: Write access

only in the commissioning state

(p0010 not equal to 0).

–

–

0x76

Parameter %s [%s]: Write access

only in the commissioning state,

download (p0010 = 29).

–

–

0x77

Parameter %s [%s] may not be

written in download.

–

–