Servo control

3.4 Torque-controlled operation

Drive Functions

70

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

HJS

>@

 

S>&@

 

S>&@

S>&@

U





 

Figure 3-6

Torque setpoint

3. Activate enable signals

OFF responses

● OFF1 and p1300 = 23

– Reaction as for OFF2

● OFF1, p1501 = "1" signal and p1300 ≠ 23

– No separate braking response; the braking response takes place by a drive that

specifies the torque.

– The pulses are suppressed when the brake application time (p1217) expires. Standstill

is detected when the actual speed value is less than the speed threshold (p1226) or

when the monitoring time (p1227) that started when speed setpoint ≤ speed threshold

(p1226) has expired.

– Power-on disable is activated.

● OFF2

– Immediate pulse suppression, the drive coasts to standstill.
– The motor brake (if parameterized) is closed immediately.
– Power-on disable is activated.

● OFF3

– Switch to speed-controlled operation
– n_set = 0 is input immediately to brake the drive along the OFF3 deceleration ramp

(p1135).

– When zero speed is detected, the motor brake (if parameterized) is closed.
– The pulses are suppressed when the motor brake application time (p1217) has

elapsed. Standstill is detected when the actual speed value is less than the speed

threshold (p1226) or when the monitoring time (p1227) that started when speed

setpoint ≤ speed threshold (p1226) has expired.

– Power-on disable is activated.