5 inputs/outputs, 1 overview of inputs/outputs – Efficient Networks Siemens Sinamics S120 User Manual
Page 484

Basic information about the drive system
12.5 Inputs/outputs
Drive Functions
484
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4
Changing scaling parameters p2000 to p2007
CAUTION
If a referenced form is selected and the reference parameters (e.g. p2000) are changed
retrospectively, the referenced values of some of the control parameters are also adjusted
to ensure that the control behavior is unaffected.
12.5
Inputs/outputs
12.5.1
Overview of inputs/outputs
The following digital/analog inputs/outputs are available:
Table 12-6 Overview of inputs/outputs
Digital
Analog
Component
Inputs
Bidirectional
inputs/outputs
Outputs
Inputs
Outputs
CU310
4
1)
4
3)
CU320
8
1)
8
2)
TB30
4
-
4
2
2
TM15
-
24
-
-
-
8
4
-
2
2
TM31
Relay outputs: 2
Temperature sensor input: 1
4
4
-
1
-
TM41
Incremental encoder emulation: 1 (see also the Function Manual)
1) Variable: floating or non-floating
2) 6 of these are "high-speed inputs"
3) 3 of these are "high-speed inputs"
Note
For detailed information about the hardware properties of I/Os, please refer to:
Reference: /GH1/ SINAMICS S120 Equipment Manual: Control Units
For detailed information about the structural relationships between all I/Os of a component
and their parameters, please refer to the function diagrams in:
Reference: /LH1/ SINAMICS S List Manual