Communication PROFIBUS DP/PROFINET IO
10.1 Communications according to PROFIdrive
Drive Functions
374
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4
Bit
Meaning
Comments
BICO
1
Setpoint static
2
Setpoint static
0
Setpoint not static
BO: r2683.2
3
Reserved
–
–
–
1
Axis moves forwards
4
Axis moves forwards
0
Axis stationary or moving backwards
BO: r2683.4
1
Axis moving backwards
5
Axis moving backwards
0
Axis stationary or moving forwards
BO: r2683.5
1
Software limit switch minus approached
6
Software limit switch minus
approached
0
Software limit switch minus not approached
BO: r2683.6
1
Software limit switch plus approached
7
Software limit switch plus
approached
0
Software limit switch plus not approached
BO: r2683.7
1
Actual position value <= cam switching position 1
8
Actual position value <= cam
switching position 1
0
Cam switching position 1 passed
BO: r2683.8
1
Actual position value <= cam switching position 2
9
Actual position value <= cam
switching position 2
0
Cam switching position 2 passed
BO: r2683.9
1
Direct output 1 active
10 Direct output 1 via the traversing
block
0
Direct output 1 not active
BO: r2683.10
1
Direct output 1 active
11 Direct output 2 via the traversing
block
0
Direct output 1 not active
BO: r2683.11
1
Fixed stop reached
12 Fixed stop reached
0
Fixed stop is not reached
BO: r2683.12
1
Fixed stop, clamping torque reached
13 Fixed stop, clamping torque
reached
0
Fixed stop, clamping torque is not reached
BO: r2683.13
1
Travel to fixed stop active
14 Travel to fixed stop active
0
Travel to fixed stop not active
BO: r2683.12
15 Reserved
–
–
–
AktSatz
See function diagram [3650]
Table 10-17 Description AktSatz (active traversing block/MDI active)
Bit
Meaning
Comments
BICO
0
Active traversing block, bit 0
–
BO: r2670.0
1
Active traversing block, bit 1
–
BO: r2670.1
2
Active traversing block, bit 2
–
BO: r2670.2
3
Active traversing block, bit 3
–
BO: r2670.3
4
Active traversing block, bit 4
–
BO: r2670.4
5
Active traversing block, bit 5
–
Active traversing block (6-bit counter)
BO: r2670.5
6..14 Reserved
–
–
–
1
MDI active
15 MDI active
0
MDI not active
BO: r2670.15