Servo control

3.9 V/f control for diagnostics

Drive Functions

86

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

V/f characteristic

The speed setpoint is converted to the frequency specification taking into account the

number of pole pairs. The synchronous frequency associated with the speed setpoint is

output (no slip compensation).

S

S

9

I>V@

S

8>9@

Figure 3-15 V/f characteristic

Function diagrams (see SINAMICS S List Manual)

● 5300 V/f control for diagnostics

Overview of key parameters (see SINAMICS S List Manual)

● p0304 rated motor voltage
● p0310 rated motor frequency
● p0311 rated motor speed
● r0313 Motor pole pair number, actual (or calculated)
● p0314 motor pole pair number
● p031 Motor voltage constant
● p0322 Maximum motor speed
● p0323 Maximum motor current
● p0640 current limit
● p1082 Maximum speed
● p1317 V/f control diagnostics activation
● p1318 V/f control ramp-up/ramp-down time
● p1319 V/f control voltage at zero frequency
● p1326 V/f control programmable characteristic frequency 4
● p1327 V/f control programmable characteristic voltage 4