Communication PROFIBUS DP/PROFINET IO

10.2 Communication via PROFIBUS DP

Drive Functions

422

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

Subscriber

The subscribers evaluate the broadcast telegrams, sent from the publishers, and use the

data which has been received as setpoints. The setpoints are used, in addition to the

setpoints received from the master, corresponding to the configured telegram structure

(p0922).

Links and taps

The links configured in the subscriber (connection to publisher) contain the following

information:
● From which publishers may input data be received?
● Which input data is there?
● A which location should the input data be used as setpoints?
Several taps are possible within a link. Several input data or input data areas, which are not

associated with one another, can be used as setpoint via a tap.
Links are possible to the device itself. This means, e.g. for a Double Motor Module, data can

be transferred from drive A to B. This internal link corresponds, as far as the timing is

concerned, to a link via PROFIBUS.

Prerequisites and limitations

The following limitations should be observed for the "slave-to-slave" communications

function:
● Drive ES Basic V5.3 SP3
● Firmware version ≥ 2.4
● Number of process data, max. per drive
● Number of links to Publishers
● Number of taps per link

Applications

For example, the following applications can be implemented using the "slave-to-slave

communications" function:
● Axis couplings (this is practical for isochronous mode)

– Angular-locked synchronism where the position reference value or position actual

value is entered

– Torque setpoint coupling (master/slave operation)

Master drive speed controlled <–> slave drive torque controlled

● Specifying binector connections from another slave