Chapter 2 Initial Operation

Power-On Checkout

28

Power-On Checkout

The power-on test includes an automatic self-test that checks the internal

microprocessors and allows the user visually to check the display. You will

observe the following sequence on the display after pressing the front panel

power switch to on.

1 All segments of the display including all annunciators will turn on for about one

second.

To review the annunciators, hold down

key as you turn on

the power supply

.

2 The GPIB address or RS-232 message will then be displayed for about one

second.

The GPIB address is set to ‘‘5’’ when the power supply is shipped from the

factory for remote interface configuration. If this is not the first time the power

supply is turned on, a different interface (RS-232) or a different GPIB address

may appear.

See "Remote Interface Configuration" in chapter 3 starting on page 56 if you

need to change the remote interface configuration.

3 The “

15V

”, “

OVP

”, “

OCP

” and “

OFF

” annunciators are on. All others are off.

The power supply will go into the

power-on / reset

state; the output is disabled

(the

OFF

annunciator turns on); the 15V/7A range is selected (the

15V

annunciator turns on); and the knob is selected for

voltage

control. Notice that

the

OVP

and

OCP

annunciator also turn on.

4

Enable the outputs.

Press the

key to enable the output. The

OFF

annunciator turns

off and the

15V

,

OVP

,

OCP

, and

CV

annunciators are lit. The

blinking

digit can

be adjusted by turning the knob. Notice that the display is in the meter mode.

‘‘Meter mode’’ means that the display shows the actual output voltage and

current.

N o t e

If the power supply detects an error during power-on self-test, the

ERROR

annunciator will turn on. See "Error Messages" for more information

starting on page 121 in chapter 5

ADDR 05

(

or

RS-232

)

Display Limit