Voltage {<voltage>| minimum | maximum|up|down, Voltage, Voltage? [minimum | maximum – Agilent Technologies E3632A User Manual

Page 88: Programmable

Advertising
background image

Chapter 4 Remote Interface Reference

Output Setting and Operation Commands

85

4

VOLTage {<voltage>| MINimum | MAXimum|UP|DOWN}

This command programs the immediate voltage level of the power supply. The

immediate level is the voltage value of the output terminals.

The

VOLTage

command changes the output of the power supply to the newly

programmed value regardless of the output range presently selected.

You can substitute ‘‘MINimum’’ or ‘‘MAXimum’’ in place of a specific value for

the voltage parameter. MIN selects the lowest voltage values of ‘‘0’’ volts.

MAX

selects the highest voltage values allowed for the selected range.

This command also increases or decreases the immediate voltage level using

the ‘‘UP’’ or ‘‘DOWN’’ parameter by a predetermined amount. The command

VOLTage:STEP

sets the amount of increase or decrease. Notice that a new

increment setting will cause an execution error -222 (Data out of range) when

the maximum or the minimum rated voltage is exceeded.

VOLTage

The following program segments show how to use the

VOLT UP

or

Example

VOLT DOWN

command to increase or decrease the output voltage with the

VOLT:STEP

command.

"VOLT:STEP 0.01"

Set the step size to 0.01 V

"VOLT UP"

Increase the output voltage

"VOLT:STEP 0.02"

Set the step size to 0.02 V

"VOLT DOWN"

Decrease the output voltage

VOLTage? [MINimum | MAXimum]

This query returns the presently programmed voltage level of the power

supply.

VOLT? MAX

and

VOLT? MIN

return the highest and lowest

programmable

voltage levels for the selected range.

Advertising