Chapter 3 Front-Panel Operation

Remote Interface Configuration

58

To Set the GPIB Address

To configure the power supply for the GPIB interface, proceed as follows:

1

Turn on the remote configuration mode.

You will see the above message on the front-panel display if the power supply

has not been changed from the factory setting. If “RS-232” appears, choose

“GPIB / 488” by turning the knob to the right.

2

Move to the GPIB address setting mode.

The address is set to “05” when the power supply is shipped from the factory.

Notice that a different GPIB address may appear if the power supply has been

changed from the factory setting.

3

Turn the knob to change the GPIB address.
The displayed address is changed when turning the knob to the right or left.

4

Save the change and turn off the I/O configuration mode.

The address is stored in

non-volatile

memory, and

does not

change when

power has been off or after a remote interface reset. The power supply displays

a message to show that the change is now in effect. If the GPIB address is not

changed, “NO CHANGE” will be displayed for one second.

N o t e

To exit the I/O configuration mode without any further changes, press the

“I/O Config” key until the “NO CHANGE” message is displayed.

GPIB / 488

ADDR 05

CHANGE SAVED

I/O Config

I/O Config

I/O Config