*TST?

This query performs a

complete

self-test of the power supply. Returns ‘‘0’’ if

the self-test passes or ‘‘1’’ or any non-zero value if it fails. If the self-test fails,

an error message is also generated with additional information on why the test

failed.

*SAV { 1 | 2 | 3 }

This command stores the present state of the power supply to the specified

location in

non-volatile

memory. Three memory locations (numbered 1, 2 and

3) are available to store operating states of the power supply. The state storage

feature ‘‘remembers’’ the states or values of the following commands:

CURR, CURR:STEP, CURR:TRIG, CURR:PROT, CURR:PROT:STAT DISP,
OUTP, OUTP:REL, TRIG:DEL, TRIG:SOUR, VOLT, VOLT:STEP, VOLT:TRIG,
VOLT:PROT, VOLT:PROT:STAT, and VOLT:RANG

To recall a stored state, you must use the same memory location used

previously to store the state.

*RCL { 1 | 2 | 3 }

This command recalls a previously stored state. To recall a stored state, you

must use the same memory location used previously to store the state.

N o t e

DISP {OFF|ON}

can be stored and recalled in remote interface mode only.

Going to local mode automatically sets the display state to ON.