LBI-39224

3-72

Site Channel Configuration List

dialog box

Send

Choose the

Send

button to send the site channel configuration data to

the respective interface module. This procedure must be performed
before the interface module will operate with the new configuration.
Only configured and configured-and-active (C and C/A prefixes)
configurations may be sent. All configuration data is sent to the MOM
Controller Board; the Audio configuration is sent directly out from
there to the respective interface module Controller Board. A "Send to
Site Successful" message will be received to confirm that the data was
received by the interface module Controller Board. Bus Slot
configuration data is compared to the current configuration at the
CEC/IMC Manager; if different, it is sent to the MOM Controller
Board (if not, no further action is taken by the system) and when the
MOM Controller Board receives this new data it will send an
acknowledgment message back to the CEC/IMC Manager, which will
then display the confirmation box: "Do you want to activate TDM Bus
Slots? OK - will cause all CTRL boards to reset." Choose

OK

to

activate TDM Bus Slots (resetting Controller Boards) with the new Bus
Slot configuration data, choose

Cancel

to not activate TDM Bus Slots

with the new Bus Slot configuration data (keeping the previous
configuration) and return to the

Site Channel Configuration List

dialog box.

Close

Choose the

Close

button to exit the

Site Channel Configuration List

dialog box and return to the CEC/IMC Manager main window. Any
"**" (unconfigured and unsaved) PIMs appearing in the
Configured/Active Sites list box will be removed and returned to the
Configurable Sites list box.

T1/E1 Interface Card-Equipped PIM Configuration

This section describes configuration for channels of T1/E1 Interface
Card-equipped PIMs (currently only MIMs, NIMs, and PIMs are so
equipped). Channel configurations are performed from the

T1/E1 Digital Site Configuration

dialog box (see Figure 18 on page 3-

39) and from the

T1/E1 Interface Card Auto-configuration

dialog

box (see Figure 19 on page 3-42). As was the case with Audio Board-
equipped site-type interface modules, only those "sites" which were
selected in the

Site Channel Configuration List

dialog box are

available for channel configuration.