Configure System

/

System Options

/

Auxiliary I/O

to display the

Auxiliary I/O Event Configuration

dialog box.

Figure 40 Auxiliary I/O Event Configuration Dialog Box

Help

Choose the

Help

button to access the Help function. (Help is also

available by pressing the F1 key).

3.18.1 I/O Event Configuration

The I/O event is displayed in the drop-down list box along the top of
the dialog box. This list box contains all of the configured events (out
of 255 possible configurable events). Select an event to view or
configure from this list box. An event must be inactive (not sent to
MOM or deleted) before any parameters can be changed. To configure
a new event select an unused event number.

All I/O events must have certain common characteristics: event type
(input or output), active state (high or low), and device type,
assignment, and bit number. These characteristics are configured in
their respective fields located in the upper left quadrant of the dialog
box. Additionally, all events may be defined to cause an "Audio Event
Warning" log at the CEC/IMC Manager on an event state change by
selecting the Log Event State Changes check box. All events except for