LBI-39224

3-35

MOM Controller Board receives this new data it will send an
acknowledgment message back to the CEC/IMC Manager, which will
then display the confirmation box: "Do you want to activate TDM Bus
Slots? OK - will cause all CTRL boards to reset." Choose

OK

to

activate TDM Bus Slots (resetting Controller Boards) with the new Bus
Slot configuration data, choose

Cancel

to not activate TDM Bus Slots

with the new Bus Slot configuration data (keeping the previous
configuration) and return to the

Site Channel Configuration List

dialog box.

Close

Choose the

Close

button to exit the

Site Channel Configuration List

dialog box and return to the CEC/IMC Manager main window. Any
"**" (unconfigured and unsaved) sites appearing in the
Configured/Active Sites list box will be removed and returned to the
Configurable Sites list box.

T1/E1 Interface Card-Equipped MIM Configuration

This section describes configuration for channels of T1/E1 Interface
Card-equipped interface modules (currently only MIMs, NIMs, and
PIMs are so equipped). Channel configurations are performed from the

T1/E1 Digital Site Configuration

dialog box (Figure 18) and from the

T1/E1 Interface Card Auto-configuration

dialog box (Figure 19). As

was the case with Audio Board-equipped site-type interface modules,
only those "sites" which were selected in the

Site Channel Configuration List

dialog box are available for channel

configuration.

Like the CEC/IMC Audio Board, each T1/E1 Interface Card
within a CEC/IMC interface module must have a unique board
address setting. This address is 1 - 8 (addresses 2 - 8 are
currently not available).