3-118

Default Module Volume
This is the default volume setting on the unselect speaker (selected
above) for incoming calls. Use the drop-down list box to select a value
from 0 thru 32.

For C3 Maestro for Windows NT the volume settings are 0 -
10, however, the actual volume range is the same.

Tone Attenuation
Console tone volume levels are determined by subtracting this setting
(dBm) from the volume of the current console module associated with
the tone. For example, if the level is set to "5," the tones will be 5 dBm
less than the voice audio at the current module. Select a dBm level
between 0 and 40 from the drop-down list box. Setting the offset
number to a large value (near 40) will effectively turn off the tones at
the console. Headsets equipped with AGC circuits may defeat this
feature.

Error Tones
Select this check box to enable the error tone when the console
determines an error has occurred. Unselect to disable the error tone.

Force Tones to Select Speaker
Select this check box to force confirmation tones and error tones to the
select speaker. Unselect to disable.

Audible Trunked/Failsoft Tones
This option is available only if the Trunked/Failsoft Display check box
in the Visual Indicators group is selected. Select this check box to
enable an audible warning tone when a trunked site goes to Failsoft
mode. Unselect to disable the audible warning tone (the visual warning
will still appear).

Emergency Indicators

Alarm Reset Required Before Emer Clear
Select this check box to force the dispatcher to reset the emergency
alarm before clearing the emergency itself. Unselect to disable this
function.