Ericsson LBI-39224 User Manual

Page 293

Advertising
background image

LBI-39224

B-5

LOGGED

WARNING

MESSAGE

LOGGED

WARNING

DATA

CAUSE/

CORRECTIVE

ACTION

W07-120:
OVERFLOW - MOM
ERROR ARRAY

(none)

A new error message has been
received, but the MOM error status
array is full. The status of the new
error will not be stored.

W08-084:
CALL BLOCK -
INTERCONSOLE

Message group value
that generated the
warning.

Unsupported message group
between consoles.

W08-112:
CALL BLOCK - NO
CIRCUIT

DVIM
device/assignment

The DVIM did not have digital
decryption channel available for a
radio-originated encrypted call.
Wide area (multisite) radio-to-radio
calls are routed.

W09-113:
CALL ROUTING -
CONTENTION

The message group,
subgroup, caller and
callee of the call that
was routed only to
dispatch consoles due
to contention with an
already active call.

Multiple units attempted to
transmit to the same callee at the
same time. The CEC/IMC will
only allow one active transmitter
on a talk group. The "rejected" call
will be routed to all dispatch
consoles but will not be routed to
other sites. This leaves the sites all
hearing the same (original)
transmitter, but the consoles
hearing all transmissions.

W09-125:
CALL ROUTING -
CONFIRM FAIL

(see below)

Confirmed Call related warnings.
This warning is generated from
multiple causes:

The caller and callee
of the failed
confirmed call. The
failure reason, as well
as a bit mask of all
required sites that did
not successfully
respond is also
included. Each bit
corresponds to a site
number (1-32):
00000001H = Site 1,
80000000H = Site 32

Radio PTT causes: A confirmed
group call did not receive working
channel assignments from all
required sites for the confirmed
group. The call will time out and
transmit in any event after 6-10
seconds.

"Time

Out"

No response received from
expected site(s).