2 appendix b - logged warning definitions – Ericsson LBI-39224 User Manual

Page 289

Advertising
background image

LBI-39224

B-1

7.2 APPENDIX B - LOGGED WARNING

DEFINITIONS

LOGGED

WARNING

MESSAGE

LOGGED

WARNING

DATA

CAUSE/

CORRECTIVE

ACTION

W00-xxx:
UNKNOWN
WARNING

(none)

A warning has been generated
within the CEC/IMC, but the
CEC/IMC Manager cannot
determine what it is. This is
usually a result of a Controller
Board residing in the system with
firmware prior to version 2.00 or
with a firmware version more
recent than the CEC/IMC
Manager's software version.
Corrective Action: Ensure all
Controller Boards in system are
equipped with firmware version
2.00 or greater and the CEC/IMC
Manager contains a software
version greater than or equal to the
most recent Controller Board
firmware being used.

W01-048:
UNDEFINED -
CALLEE TYPE

The callee type value
that generated the
warning.

Unknown callee type was found.

W01-049:
UNDEFINED -
CALLER TYPE

The caller type value
that generated the
warning.

Unknown caller type was found.

W02-028:
OUT OF RANGE -
CONSOLE NUMBER

Console number that
generated the
warning.

Console number found that was not
in the allowed range of 1 – 32.

W02-032:
OUT OF RANGE -
BUS_SLOT

Low byte contains
bus number. High
byte contains slot
number.

Bus or slot number found that was
greater than the maximum number
allowed.

W02-033:
OUT OF RANGE -
AUDIO CHANNEL

Audio channel
number that generated
the warning.

Audio channel number found that
was not in the allowed range.

Advertising