Ericsson LBI-39224 User Manual

Page 216

Advertising
background image

LBI-39224

3-186

prevent overburdening the CEC/IMC Manager's warning system with
auxiliary I/O state change warnings.

An output event state change will be logged with the following warning:

mm/dd/yy hh:mm:ss FF MIM 1 W17-130 Auxiliary I/O - State Change
Output 1 Active [Bit 0 High] Trig: E02-22

The output number, active/inactive state, bit value, absolute state
(high/low) and trigger description will match the current event's data.
The possible "Trig:" descriptions are:

Console Key Press

– Station

Busy

– Select

Busy

– Emergency
– Any

Error

– Error

Exx-yyy (shown)

– Warning

Wxx-yyy

An input event's state change warning is similar except the trigger field
is not displayed.

Read and Delete I/O Event Definitions

Delete

Choose the

Delete

button to change the selected I/O event from

enabled to modified-not-sent. The selected event remains on the
CEC/IMC Manager hard disk, but is deleted from the CEC/IMC
NOVRAM.

Default

Choose the

Default

button to return the I/O event entry to the "default"

(unconfigured) condition. If the event is enabled (sent to the
CEC/IMC), it first must be deleted from the CEC/IMC. A confirm
dialog box is displayed which will allow the request to be canceled, if
necessary.

Read Disk

Choose the

Read Disk

button to view the I/O event configurations

currently stored at the CEC/IMC Manager hard disk.

Save and Send I/O Event Definitions

After the I/O events are defined at the CEC/IMC Manager, the
definitions must be sent to the MOM Controller Board. If the I/O event

Advertising