Ericsson LBI-39224 User Manual

Page 83

Advertising
background image

LBI-39224

3-53

Save and Send NIM Audio Board Configurations

When channel configuration of the selected NIM is complete, the

Site Channel Configuration

dialog box changes must be sent to the

CEC/IMC before the changes will take effect. This reprograms the
NIM Controller Boards. However, it is important to save the new
configuration prior to sending it to the CEC/IMC because a send will
send the last configuration saved to disk; saving first ensures that the
actual CEC/IMC channel configuration will be the same as the channel
configuration stored on the CEC/IMC Manager hard disk. To save and
send configurations, action is required first in the

Site Channel Configuration

dialog box and then in the

Site Channel Configuration List

dialog box.

Site Channel Configuration

dialog box

Save

Choose the

Save

button to perform an immediate save of the currently

selected site-type interface module's channel configuration. Other
"sites" displayed in the list box located at the top of the dialog box are
not saved. This channel configuration is saved on the CEC/IMC
Manager hard disk drive. Any previous channel configuration for the
"site," if present, is erased and replaced with the current channel
configuration. If the CEC/IMC Manager is running remotely or as a
part of the EDACS Network Manager, this configuration is saved on the
CEC/IMC Manager server, typically local to the CEC/IMC; it is not
saved at the remote location.

Save As...

Choose the

Save As…

button to allow the currently selected NIM

channel configurations to be saved as a different NIM. It is provided to
speed configurations when similar configurations are required. Upon
choosing

Save As…

a small dialog box (See Figure 17) will appear

which allows selection of a new NIM number. Select the desired NIM
number from one of the choices in the drop-down list box, the choices
listed are the selected NIMs in the Configured/Active Sites list box.
Like

Save

,

Save As…

stores channel configuration on the CEC/IMC

Manager server.

For example, if "Site 3" is the currently selected site-type interface
module and "Site 12" requires similar configuration settings, this button
may be used to save the "Site 3" configuration as "Site 12" (save to
"12"). The new "site" may then be changed later, as required, by

Advertising