LBI-39224

3-198

Read Disk

Choose the

Read Disk

button to view the current configuration stored

at the CEC/IMC Manager hard disk.

Read CEC/IMC

Choose the

Read CEC/IMC

button to view the current Multisite

configuration at the CEC/IMC.

Close

Choose the

Close

button to exit the

System Options

dialog box and

return to the CEC/IMC Manager main window. If any changes have
been made and not saved, you will be prompted
(

Write Changes to Disk?

) to save and exit (

Yes

), exit without saving

(

No

), or cancel the

Close

command and remain in the dialog box

(

Cancel

).

Timer Master Enable/Disable

The Multisite Unit Logout check box in the

System Options

dialog

box provides a master enable/disable function for all multisite unit
timers. The timers at the MOM (Monitor Module) must be enabled if
the timer-based multisite unit logout option is used. Enable the timers
from this dialog box. With the Multisite Unit Logout check box
selected (enabled), the multisite unit logout feature operates normally; a
unit will be logged out from the multisite call routing process when its
timer expires. If the Multisite Unit Logout check box is unselected
(disabled), all multisite unit timers stop; therefore, a unit will not be
logged out from the multisite call routing process as long as it remains
logged into the EDACS trunked site.

Multisite Monitor

The Multisite Channel Monitoring function is available on a limited
basis to prevent GSC bus overloading. If the average GSC loading is at
an acceptable level, i.e. below the "entry" threshold, the MOM
Controller will command all MIM type devices to begin putting
secondary drops on the GSC bus. The CAM will intercept the
secondary drops and send them to the CAL. The Network Manager
will receive multisite channel monitoring information from the CAL
and will use this information to display channel drops for secondary
sites. Once this function is enabled, the MOM Controller will continue
to monitor the GSC loading. If the average loading exceeds the
"active" threshold, the MOM Controller will command all MIM type