Ericsson LBI-39224 User Manual

Page 194

Advertising
background image

LBI-39224

3-164

The maximum number of conventional channels configurable
for Causeway operation may be limited by EDACS license
privileges. See FEATURE DATA in Chapter 4 for more
information.

None
Select this option button if no Causeway operation is desired
for the currently selected conventional channel.

Patch
Select this option button if the currently selected conventional
channel requires Causeway patch operation. Entry of a GID
number is also required (see Group ID (GID)).

Simulselect
Select this option button if the currently selected conventional
channel requires Causeway simulselect operation. Entry of a
GID number is also required.

Group ID (GID)
If Patch or Simulselect is selected, a number must be entered
in this text box to specify the group ID number for the
Causeway patch/simulselect. If the EDACS trunked system is
equipped with a System Manager, the entered number should
be a valid GID number in the System Manager's GID database.
Upon entering a valid GID number, its alias (name) will be
displayed per the current GID database stored on the
CEC/IMC Manager's hard disk drive. If no alias exists for the
entered GID, "NO_ALIAS" will be displayed. Group ID
(GID) range = 0 (zero) – 2047.

Delete

Choose the

Delete

button to delete the currently selected conventional

channel configuration and return to the default configuration. A
Message Box will be displayed asking you to confirm (

Yes

) or (

No

)

the

Delete

command.

Save and Send High-level Configurations

Any

Conventional Channel Configuration

dialog box changes must

be sent before the changes will come into effect at the CEC/IMC. This

NOTE

Advertising