11.1 General User Parameters

Integrating the TNC interfaces to external devices:
Data format and transmission stop

Input value: number between 0 and 255
The entry value is the sum of the individual values.

MP5020

Function

Selections

Value

• Number of data bits

7

data bits (ASCII code, 8th bit = parity) .................................... +0

8

data bits (ASCII code, 9th bit = parity) .................................... +1

• Block Check Character (BCC)

BCC can be any character ............................................................ +0
BCC control character not allowed ............................................... +2

• Transmission stop with RTS

Active ........................................................................................... +4
Inactive ......................................................................................... +0

• Transmission stop with DC3

Active ........................................................................................... +8
Inactive ......................................................................................... +0

• Character parity

Even ............................................................................................. +0
Odd ............................................................................................. +16

• Character parity

Not desired ................................................................................... +0
Desired ....................................................................................... +32

• Number of stop bits

1

1

/

2

stop bits ................................................................................ +0

2

stop bits .............................................................................. +64

1

stop bit .............................................................................. +128

1

stop bit .............................................................................. +192

Example

To adapt the TNC interface to an external non-
HEIDENHAIN device, use the following setting:
8 data bits, BCC any character, transmission stop with DC3, even charac-
ter parity, character parity desired, 2 stop bits.

Input value:

1+0+8+0+32+64 = 105, so enter 105 for MP 5020.

Interface type

MP5030

Function

Selections

Value

• Interface type

Standard .......................................................................................... 0
Interface for blockwise transfer ...................................................... 1