TNC 360

2-14

2

Manual Operation and Setup

Fig. 2.13:

Probing for the datum in the Z axis

0

e.g.

ENT

I

or

Y

X

Z

1

2.5 Setting the Datum with the 3D Touch Probe System

The following functions for setting the datum on an aligned workpiece are
listed for in the TCH PROBE menu:

• Datum setting in any axis with

SURFACE = DATUM

• Setting a corner as datum with

CORNER = DATUM

• Setting the datum at a circle center with

CIRCLE CENTER = DATUM

Setting the datum in a specific axis

Select the probe function SURFACE = DATUM.

Move the touch probe to a starting position near the touch point.

SURFACE = DATUM

X + X – Y + Y – Z + Z –

Select the probing direction and the axis in which you wish to set the datum,
for example Z in the Z– direction.

Probe the workpiece.