Fig. 2.16:

Probing an outside cylindrical
surface to find the center

or

2.5

Setting the Datum with the 3D Touch Probe System

Y

X

X–

X+

Y+

Y–

3

1

2

4

Outside circle

Select the CIRCLE CENTER = DATUM probe function.

Move the touch probe to a starting position near the first touch point

1

outside of the circle.

CIRCLE CENTER = DATUM

X + X – Y + Y –

Select the probing direction.

Probe the workpiece.

Repeat the probing process for points

2

,

3

and

4

(see Fig. 2.16).

Enter the coordinates of the circle center.

After the probing procedure is completed, the TNC displays the coordi-
nates of the circle center and the circle radius PR.