Configuring Plant Data

19�2 Plant groups

Since the Solar-Log™ can manage up to 100 inverters at the same time, it is helpful to divide these invert-

ers into groups. To provide a clearer overview, these groups are then shown in all selection dialog boxes.

The data from each plant group can be presented on its own large external display. Each plant group can

also be combined with its own consumption meter.

A name, a specific tariff payment and/or a yearly target value can be assigned to each plant group, Plant

groups are therefore also suitable for managing system expansions.

Example: If a plant initially has 5 inverters and 30 kWp and is extended at a later date with 3 more invert-

ers and 20 kWp, this addition can be conveniently managed as a separate group with one Solar-Log™.

Individual inverters can then be selected from the group concerned. Plant groups are defined starting with

15 inverters. A maximum of 10 plant groups can be defined.

Note

When using several plant groups, only one plant group can be used with a tariff mode

with self-consumption refund or self-consumption.

Note

Plant groups cannot be created for Solar-Log 200 and Solar-Log 500 devices.

Procedure:

Select

Configuration | Plant | Plant groups

from the menu.

To

use

Plant buttons

, the button needs to be

activated

.

Under

Name

, a plant group can be uniquely

labeled.

The devices recognized during the Device Detection are now allocated into the device groups.

Click on

to

display

a

list

of all of the devices.

Place a

check

in the box next to the devices that belong to this plant group and select

Apply

.

For the next steps, additional plant groups and their devices can be defined in the same way.

SAVE

settings.

19�3 Graphic

This function is deactivated by default.

Advanced Configuration

needs to be activated under

Configura-

tion | System

.

The scale of the graphic for individual devices can be adjusted in the graphic menu. Nothing usually has

to be changed here, as Solar-Log™ automatically calculates the values for the generator power input. The

values can be adapted to your own data.

For each period (day, month, year, total) the maximum value represented in kW can be entered (except

Day, which is a value in W).

The graph shows these values on the Y-axis.

Changes become effective when a new graph is displayed or after updating a displayed graph.

The function can be activated in general with the switch

Graphic Auto scaling

The auto scaling option al-