Direct Device Configurations (Solar-Log 1000)

26�4 Initial configuration

The "Initial configuration" menu is opened automatically at the initial startup. However, it can be opened

again at any time afterwards by going to the Config. | Start | Initial Configuration menu.

The initial configuration is made through dialog boxes:

Time settings and IP address

Inverter selection

Power meter on S0 input

Performing inverter detection (Config. / Start / Inverter detection)

Procedure:

Select the Config. | Start | Initial Configuration menu.

The time setting and IP address are displayed in the dialog box.

26�4�1 Time settings and IP address

The clock time is factory-set, but it may be lost due to long periods of storage.

System settings

The time zone, date and summertime values must be set correctly, so that no incorrect statuses or results

are obtained during monitoring and graph display, e.g. when e-mail messages are sent or when a curve is

displayed on the day graph.

Network Settings section

IP Address

In general, the IP address only needs to be changed or checked if Solar Log 1000 is to be connected to a

router without the DHCP service, or connected directly to a PC.

The IP address is to DHCP by default. This can be changed here to a network address which is appropriate

for the local network.

After saving, the Solar-Log 1000.restarts automatically

Obtain IP address automatically

The IP address can be obtained automatically if the Solar-Log 1000 is connected to an Internet router with

the DHCP service enabled.

After saving and the automatic restart, the new IP address is displayed accordingly. The Solar-Log 1000

can now be reached at this address and it has automatic access to the Internet.

Procedure

Enter all the related data (see above list)

Touch

Save

and then

Next

to go to the next dialog.