Configuring connected devices

18�2 Defining Smart Home / Smart Energy switches

The switches that are to be used for the Smart Home / Smart Energy function - switching on appliances

in certain production scenarios - have to be defined and configured. A maximum of 10 switches is available.

Select the definition in the

Configuration | Devices | Definition

menu. The switches used are defined

here. The next step is to detect these defined devices in the

Configuration | Devices | Detection

menu.

The control logic for the defined switches can be programmed in the

Configuration | Special Functions |

Smart Home / Smart Energy

menu.

Switch configuration menu

In the section, the switches 1-10 can be selected and their hardware can be defined.

Procedure:

Select

switch place

Enter

the switch name (max. 16 characters)

Define

the switch

type

The following switch types are available:

Internal relay (only Solar-Log 1200 and 2000)

Allnet 3075/3076

Allnet 3000

Gude 1100/1101

Gude 1002

Allnet 3075/3076 V2

Allnet 3073

Solar-Log™ Smart Relay Box (The connection via RS485 cannot be combined with inverters con-

nected to the RS485 bus)

Gude 2301

Solar-Log Smart Relay Station 3x 3.5kW

Solar-Log Smart Relay Station 1x 3.5kW

Belkin WeMo Socket

Belkin WeMo Insight

Allnet 3075 V3

Select the corresponding

switch type

Activate

the switch

The

IP address of the switch

needs to be entered when the switch is to be controlled via an IP ad-

dress (all of the relays other than the internal relay and the Smart Relay Box).
The RS485 used needs to be selected for the Smart Relay Box.

There is a prompt for the RE485 connection and also the desired relay with the Smart Relay Box.
Enter the number of the relay (0-7) is this field.

The sub-address (1-4 for each relay) needs to be defined when using the Gude 1002 and Gude 2301
(4 Relay).

SAVE

settings.

If several switches are to be used, repeat these steps for each switch.

Note

Refer to the manufacturer's manuals to configure the IP addresses for the IP sockets.