Connecting accessories

12�7 Wiring for RS485 meter

The meter's RS485 output can be connected to any RS485 interface (A, B and C) on the Solar-Log™.

Overview

2-pin wiring

The communication address does not have to be assigned.

Installation steps

Switch off the inverters and Solar-Log™.

Connect the meter to the Solar-Log™.

The wiring is done using a self-made, shielded 2-wire data cable and a 4-pin or 6-pin terminal block con-

nector.

Procedure

Connect the wires for the connecting line as shown in the following diagram.

Wiring for RS485 meter

Solar-Log™ RS485 ter-

minal block connector

Inepro 75D

terminal block connec-

tor

Article number: 255420

Inepro 1250D

terminal block connec-

tor

Article number: 255421

Utility meter terminal

strip

Article Number: 255385

PIN

PIN

PIN

PIN

1

8 - 485A

11 - 485A

22 - B

4

7 - 485B

10 - 485B

23 - A

Insert the terminal block connector into the Solar-Log™ RS485 A, RS485/422 B or RS485/422 C
socket.

Perform a device detection: The power meter is connected to the system as if it were an inverter.

Configure the power meter functions under

Configuration | Device | Configuration

. See Page

95for more information.

Inverter mode

Total yield meter

Consumption meter

Utility Meter (U) (only Solar-Log 1000 and 2000)

Utility Meter (U+I) (only Solar-Log 1000 and 2000)

Sub-consumer

Note

Only one Inepro RS 485 meter can be used for
each Solar-Log™ interface.