Solare Datensysteme Solar-Log User Manual

Page 95

Advertising
background image

95

Configuring connected devices

18�5 Configuring devices

After the Device Detection has been successfully completed, the detected devices have to be defined

in the

Configuration | Devices | Configuration

menu.

Depending on the device, different settings might be needed for the configuration.

The following devices are listed in the device overview:

Inverters

Power meters and current transformers (with Solar-Log METER)

Sensors

Procedure:

Select the device that needs to be configured in the Device Configuration section.

Depending on the device type, different configuration boxes appear.

The sections below—Module Fields, Power Output and Descriptions—are to a large extent identical
Enter the module field, connected generator power and description

18�5�1 Configuring inverters

The following values have to be configured for inverters:

Maximum AC Power

Pac Correction Factor

Module field

Generator Power and MPP tracker output (according to the string plan)

Labels or names of the inverters and/or MPP trackers.

Procedure:

Select

Device

Enter

the maximum AC power

from the inverter's data specification

in the section: Module Field, Power

and Name.

Enter the Pac correction

factor

If the power yield displayed by the inverter is compared with the calibrated current meter, devi-
ations are detected. An approximate correction factor can be defined in order to compensate for
this inaccuracy.

All yield data are stored internally without any correction factor. This factor is applied only when the

data are displayed. The factor can therefore be adjusted at any time.

The formula for calculating the correction factor is as follows:

Yield on power meter / Yield at inverter * 1000

If the inverter does not have a display, the correction factor must be left at 1000 initially, and the fac-

tor can then be determined after about a week or at later times.

Define

the module field

Inverters can be assigned to be different module fields. See Chapter “18.5.6 Module Fields”.

Generator Power
The connected power of the individual inverters in Wp. The total power can be calculated using the
formula: Module power * Number of modules. The output does not have to be entered. It is calcu-
lated from the total generator power values that have been entered for the

Mpp Tracker

.

The

generator power

for every

tracker

needs to be entered if the inverter has several

MPP track-

ers.

IA distinct

name can be assigned to every generator/MPP tracker in the

Label

box.