External power meters/net energy meters – Solare Datensysteme Solar-Log User Manual

Page 53

Advertising
background image

53

Connecting accessories

External power meters/net energy meters

With multiple phase meters, a basic distinction is made between phase-exact and net energy meters.

Net energy meters provide the total values from all three phases. The meter calculates the total output

(also to and from the grid) of the individual phases and provides this total as a single value.

In the example:

Phase 1 supplies 3 kW via an inverter (single phase).

Phase 2 refers to 2 kW (energy)

Phase 3 refers to 1 kW (energy)

With an accumulating meter, this results in a total of 0 kW.

An example of an net energy meter is the Janitza UMG 104 and the Inepro Pro380-Mod.

Advertising