Connecting accessories

Procedure

The four wires in the connection cable must be connected to the 4-pin terminal block connector on
the Solar-Log™.

Connect the wires according to the following diagram:

Impor-

tant!

Replacing the connection wires may cause damage to the sensor.

Sensor Box Professional Plus

RS485 Solar-Log™

Connection cable

Sensor Box Professional

Plus

PIN

Assignment

1 (Data +)

Brown: Data + A

2 (+12V)

Red: 12 V

DC

3 (Ground)

Black: GND

4 (Data -)

Orange: Data - B

Installation

When the Solar-Log™ is switched on, the Sensor Box Professional Plus is also automatically powered. Then

the Sensor Box Professional Plus must be configured to the desired RS485 interface:

Select "M&T Sensor" and the corresponding bus for the initial configuration.

Perform device detection:

The Sensor Box Professional Plus is integrated into the system like an inverter.

The rest of the configuration for the environmental data is carried out via the Solar-Log™'s web
interface.