Other connections

13�2 Relay (only Solar-Log 1000, 1200 and 2000)

The Solar-Log™ has a potential-free control relay, which is activated under the following conditions:

Alarm contact triggered

Active power reduction activated

Optimization of self-consumption

The relay may be loaded with a maximum of 24 V DC and max. 2 A / ohm resistive load.

A 230 V appliance must be connected via another load relay.

Connection

Fig.: Relay connection diagram

Wiring

The wiring is done using the supplied 3-pin connector;

usually pin 1 and pin 2 are used.

In the Off state,

pin 1-2 are open

and pin 2-3 are closed.

In the On state (alarm/fault/power reduction activated),

and pin 1-2 are closed.

pin 2-3 are open

13�3 USB

Solar-Log™ 300, 1000, 1200 and 2000 have a USB connection. This USB connection can only be used for

USB sticks and not for a direct PC connection.

Note

When a USB stick is connected, the Solar-Log™ automatically saves a backup in the

backup folder. A maximum of 10 backup files are saved in the directory. Older backup

files are automatically deleted.

The backup is saved on the USB stick in the directory /Backup with the following file names:

solarlog_backup_YYMMDD.dat
YYMMDD = year, month and day - each two digits, e.g.
140312 is then 12 March 2014