Connecting accessories

12�4 Large External Displays

Large external displays can be connected to the Solar-Log™ via two interfaces:

Connection via RS485

S0 pulse output

The connection via RS485 is preferred Cable lengths can be up to 1000 meters and the data which is dis-

played on the Solar-Log™ can specified.

The large external display function is not enabled by default. To use a proxy

Display advanced configura-

tion

needs to be activated under

Configuration | System

.

Note

If inverters that use the RS422 connection are connected to this interface (e.g. Fronius,

AEG, Riello), then it is not possible to connect a display to this bus.

If the display is connected via the same cable as the inverters, the display must be con-

figured accordingly in the interface parameters.

Connection via the RS485/422 interface
Wiring for displays made by Schneider Displaytechnik

The wiring consists of a 3-pin control cable, (3x0.5 mm

2

) and terminal block connector.

Schneider Large displays

RS485 Solar-Log™

Terminal block connec-

tor

Schneider Display

PIN

Assignment

1 (Data +)

A

3 (Ground)

GND

4 (Data -)

B

Further information about the connection can be obtained from the manufacturer of the display.

Wiring for displays from RiCo Electronic

The wiring consists of a 2-pin control cable, (2x0.5 mm

2

) and terminal block connector.

RiCo Large displays

RS485 Solar-Log™

Terminal block connec-

tor

RiCo Display

PIN

Assignment

1 (Data +)

Pin 1 - Data +

4 (Data -)

Pin 2 - Data -

Further information about the connection can be obtained from the manufacturer of the display.