Connecting accessories

Connection through S0 output

If the S0 output is used, only the current feed-in power can be transmitted in the form of a pulse sequence.

The display has to calculate the power output and total yield by itself.

Wiring for a contact-controlled S0 output

Example: RiCo Electronic

The wiring consists of a 2-pin shielded cable (2x0.6 mm)

(max. length 100 m) and terminal block connector.

RiCo Large displays

RS485 Solar-Log™

Display

PIN

Assignment

5

S0-

6

S0+

Further information about the connection can be obtained from the manufacturer of the display.

Pulse factor

In the standard setting, Solar-Log™ sends 1000 pulses/kWh over the S0 output. The pulse factor must be

configured according to the size of the plant (kWp) in the

Configuration | Devices | Definition | External

Display

menu.

Pulse factor / plant size

Plant size kWp

Pulse factor

30 kWp

2000

60 kWp

1000

100 kWp

600

150 kWp

400

300 kWp

200

600 kWp

100

Note

The impulse factor in the Solar-Log™ and the connected device has to be identical.