Connecting accessories

12�9 Solar-Log™ Smart Relay Box

The Smart Relay Box makes it possible to switch 8 relays via the Smart Home control logic depending on

the current production (surplus).

The Relay Box has:

4 inverter contacts

4 make contracts

Characteristics of the relays:

Maximum current load:

0.5 A @ 120 V

AC

0.25 A @ 240 V

AC

1 A @ 30V

DC

0.3 A @ 110V

DC

Procedure

:

Connect the Relay Box to the RS485 bus of the Solar-Log™ according to the following diagram:

Relay Box

Wiring

Terminal block connec-

tor RS485 Solar-Log™

Relay Box

Terminal block connec-

tor

Article Number: 255656

PIN

PIN

1

Data + (Y)

4

Data - (G)

Device detection is not necessary for this device.

The device only has to be selected from the

Configuration | Special Functions | Smart Home or

Smart Energy

menu to be activated.

The power comes from the top-hat-rail power supply that was included with the Relay Box.

Note

The Relay Box has to be defined and activated as a switch in the Configuration |
Devices | Definition | Smart Home to be able to configure it.
For more information, refer to the chapter:
=>

18.2 Defining the Smart Home switches.

=>

23.1 Programming the Smart Home control logic.

Note

The Solar-Log™ Smart Relay Box cannot be connected together with inverters on an

RS485 interface. The Relay Box requires its own separate RS485 bus.

It is possible to combine with Utility Meter, RS485 meters and sensors.