Special functions

23 Special functions

The following functions are available in the special functions section:

Smart Home or Smart Energy

Feed-In Management

Direct Marketing (has to be activated with a license code)

23�1 Setting up the Smart Home or Smart Energy Control Logic

The Smart Home function is managed according to pre-defined profiles. The following profile options are

available:

Surplus management

This profile is defined based on two thresholds. The threshold is defined with an

upper threshold for

activation

and a

lower threshold for deactivation

.

Deep freezer - with a temperature sensor

A switchable socket with a temperature sensor (option with the Gude connection) is required to use

this profile. The threshold is defined with an

upper threshold for activation

and a

lower threshold for

deactivation

. A

temperature limit

is defined as an additional parameter. When the defined temper-

ature limit is reached, the Solar-Log™ switches the deep freezer on for a

period of time

according to

the settings.

Deep freezer - without a temperature sensor

This profile is defined based on two thresholds. The threshold is defined with an

upper threshold for

activation

and a

lower threshold for deactivation

.

In addition to the thresholds, two

safeguard periods

to switch on the appliance can be defined.

Heat pump with a grid company blocking signal

Heat pumps can have a control input for a grid company blocking signal. This input is used by grid op-

erators via ripple control receivers to switch on heat pumps at a certain time. If a heat pump can now

be run with PV power, this input can be used to switch on the heat pumps in relation to the amount of

power being produced. The relay is then turned off during periods with a PV surplus--when the heat

pumps "may" run. When no PV surplus is available, the heat pumps remain deactivated. There are

three configurable periods available to avoid a cool down during periods with a longer deactivation,

e.g. during periods of bad weather. During such periods, the heat pumps are enabled and - if required -

power is purchased from the grid.

This profile is defined based on two thresholds and three periods of continuous operation. The periods

of continuous operation are defined based on the:

Time from/to and

Month from/to

.

Vaillant heat pump with a grid company blocking signal
This profile is especially pre-configured for Vaillant heat pumps. The function and configuration
corresponds to the "heat pump with a grid company blocking signal" profile.