Optional Connections

Note

We recommend checking and cleaning SIM cards once a year.
The contact points of the SIM card could start corroding due to humidity and should
be cleaned regularly to ensure trouble-free operations.

9�2 Solar-Log™ Meter (Solar-Log 300 and 1200)

The Solar-Log Meter version of the Solar-Log™ has an integrated interface to connect up to six current

transformers (CTs). This optional Meter interface makes it possible to measure generating units (produc-

tion meter) and consumption from individual appliances.

Fig.: Connection for current transformers (Solar-Log™ Meter)

The current transformers (CTs) can record the current flow (AC) of one or two phase appliances in various

combinations. The output is calculated based on a defined reference voltage or one calculated by the

Solar-Log™.

Note

For Solar-Log 300 and 200 Meter the installation direction of the current transformer

(CT) is not relevant, since the current flow direction can not be determined. It is missing

to a direct voltage measurement.

Combinations:

2x3 Phases

1x3 Phases + 3x1 Phase

6x1 Phase

3x2 Phases

2x2 Phases + 2x1 Phase

1x2 Phases + 4x1 Phase