Time, Mgmt class, Input format – Efficient Networks 107-0001-000 User Manual

Page 59: Parameters, Response, Time -29

Advertising
background image

Efficient Networks

®

Router family

Command Line Interface Guide

Chapter 2: Status Commands

Efficient Networks

®

Page 2-29

time

Displays or changes the current time on the router’s clock. To change the current
date, use the command

date

.

Automatic SNTP requests are generated if the system needs to get the time. You can
specify an SNTP server using the command

sntp server

and a UTC offset with the

command

sntp offset

.

Mgmt Class

All (R/W)

Input Format

time <hh:mm:ss>

Parameters

Response

When entered with no parameters:

When entered with parameters:

***

When entered with no parameters, current time and date is
displayed.

<hh>

a

a

Integer, 1 - 23

Hour parameter.

<mm>

b

b

Integer, 0 - 59

Minute parameter.

<ss>

b

Second parameter.

-> time

BootTime: 5/18/2001 at 11:57:12

Current time: 5/18/2001 at 12:00:01

-> time 1:01:01

Time set to UTC-420, 5/18/2001 at 1:01:01.074

Time adjusted for (-) 0 days 11 hours 49 minutes 34 seconds