Fll_ctl0, fll+ control register 0 – Texas Instruments MSP430x4xx User Manual

Page 123

Advertising
background image

FLL+ Clock Module Registers

4-14

FLL+ Clock Module

FLL_CTL0, FLL+ Control Register 0

7

6

5

4

3

2

1

0

DCOPLUS

XTS_FLL

XCAPxPF

XT2OF

XT1OF

LFOF

DCOF

rw−0

rw−0

rw−0

rw−0

r0

r0

r−(1)

r−1

† Not present in MSP430x41x, MSP430x42x devices

DCOPLUS

Bit 7

DCO output pre-divider. This bit selects if the DCO output is pre-divided
before sourcing MCLK or SMCLK. The division rate is selected with the
FLL_DIV bits
0

DCO output is divided

1

DCO output is not divided

XTS_FLL

Bit 6

LFTX1 mode select
0

Low frequency mode

1

High frequency mode

XCAPxPF

Bits
5−4

Oscillator capacitor selection. These bits select the effective capacitance
seen by the LFXT1 crystal or resonator when XTS_FLL = 0.
00

~1 pF

01

~6 pF

10

~8 pF

11

~10 pF

XT2OF

Bit 3

XT2 oscillator fault. Not present in MSP430x41x, MSP430x42x devices.
0

No fault condition present

1

Fault condition present

XT1OF

Bit 2

LFXT1 high frequency oscillator fault
0

No fault condition present

1

Fault condition present

LFOF

Bit 1

LFXT1 low frequency oscillator fault
0

No fault condition present

1

Fault condition present

DCOF

Bit 0

DCO oscillator fault
0

No fault condition present

1

Fault condition present