Scan IF Operation

24-27

Scan IF

24.2.5 Scan IF Interrupts

The Scan IF has one interrupt vector for seven interrupt flags listed in
Table 24−7. Each interrupt flag has its own interrupt enable bit. When an
interrupt is enabled, and the GIE bit is set, the interrupt flag will generate an
interrupt. The interrupt flags are not automatically cleared. They must be
cleared with software.

Table 24−7.Scan IF Interrupts

Interrupt

Flag

Interrupt Condition

SIFIFG0

SIFIFG0 is set by one of the AFE SIFxOUT outputs selected with the
SIFIFGSETx bits.

SIFIFG1

SIFIFG1 is set by the rising edge of the SIFSTOP(tsm) signal.

SIFIFG2

SIFIFG2 is set at the start of a TSM sequence.

SIFIFG3

SIFIFG3 is set at different count intervals of the SIFCNT1 counter,
selected with the SIFIS1x bits

.

SIFIFG4

SIFIFG4 is set at different count intervals of the SIFCNT2 counter,
selected with the SIFIS2x bits.

SIFIFG5

SIFIFG5 is set when the PSM transitions to a state with Q6 set.

SIFIFG6

SIFIFG6 is set when the PSM transitions to a state with Q7 set.

Interrupt flags SIFIFG3 and SIFIFG4 have hysteresis so that the interrupt flag
is set only once if the counter oscillates around the interrupt level as shown in
Figure 24−13.

Figure 24−13. Interrupt Hysteresis Shown For Modulo 4 Interrupt Generation

1

2

3

4

5

6

7

8

0

255

9

SIFCNT1

Interrupt Flag Not Set

Interrupt Flag Is Set