Texas Instruments MSP430x4xx User Manual
Page 472

Scan IF Operation
24-12
Scan IF
For each input there are two DAC registers to set the reference level as listed
in Table 24−3. Together with the last stored output of the comparator,
SIFxOUT, the two levels can be used as an analog hysteresis as shown in
Figure 24−6. The individual settings for the four inputs can be used to
compensate for mismatches between the sensors.
Table 24−3.Selected DAC Registers
Selected Output Bit,
SIFxOUT
Last Value of
SIFxOUT
DAC Register Used
SIF0OUT
0
SIFDACR0
1
SIFDACR1
SIF1OUT
0
SIFDACR2
1
SIFDACR3
SIF2OUT
0
SIFDACR4
1
SIFDACR5
SIF3OUT
0
SIFDACR6
1
SIFDACR7
Figure 24−6. Analog Hysteresis With DAC Registers
DAC Output Voltage
Input Voltage
SIF1OUT
Time
SIFDACR2
SIFDACR3
When TESTDX = 1, the SIFDACR6 and SIFDACR7 registers are used as the
comparator reference as described in Table 24−4.
Table 24−4.DAC Register Select When TESTDX = 1
SIFTESTS1(tsm)
DAC Register Used
0
SIFDACR6
1
SIFDACR7