Scan IF Operation

24-12

Scan IF

For each input there are two DAC registers to set the reference level as listed
in Table 24−3. Together with the last stored output of the comparator,
SIFxOUT, the two levels can be used as an analog hysteresis as shown in
Figure 24−6. The individual settings for the four inputs can be used to
compensate for mismatches between the sensors.

Table 24−3.Selected DAC Registers

Selected Output Bit,

SIFxOUT

Last Value of

SIFxOUT

DAC Register Used

SIF0OUT

0

SIFDACR0

1

SIFDACR1

SIF1OUT

0

SIFDACR2

1

SIFDACR3

SIF2OUT

0

SIFDACR4

1

SIFDACR5

SIF3OUT

0

SIFDACR6

1

SIFDACR7

Figure 24−6. Analog Hysteresis With DAC Registers

DAC Output Voltage

Input Voltage

SIF1OUT

Time

SIFDACR2

SIFDACR3

When TESTDX = 1, the SIFDACR6 and SIFDACR7 registers are used as the
comparator reference as described in Table 24−4.

Table 24−4.DAC Register Select When TESTDX = 1

SIFTESTS1(tsm)

DAC Register Used

0

SIFDACR6

1

SIFDACR7