20.2.8 Using the Integrated Temperature Sensor

To use the on-chip temperature sensor, the user selects the analog input
channel INCHx = 1010. Any other configuration is done as if an external
channel was selected, including reference selection, conversion-memory
selection, etc.

The typical temperature sensor transfer function is shown in Figure 20−10.
When using the temperature sensor, the sample period must be greater than
30

µ

s. The temperature sensor offset error can be large, and may need to be

calibrated for most applications. See device-specific datasheet for
parameters.

Selecting the temperature sensor automatically turns on the on-chip reference
generator as a voltage source for the temperature sensor. However, it does not
enable the V

REF+

output or affect the reference selections for the conversion.

The reference choices for converting the temperature sensor are the same as
with any other channel.

Figure 20−10. Typical Temperature Sensor Transfer Function

Celsius

Volts

0

50

100

1.000

0.800

0.900

1.100

1.200

1.300

−50

0.700

V

TEMP

=0.00355(TEMP

C

)+0.986