LCD_A Controller

To source the bias voltages V2 − V4 externally, REXT is set. This also disables
the internal bias generation. Typically an equally weighted resistor divider is
used with resistors ranging from 100 k

W

to 1 M

W.

When using an external

resistor divider, the V

LCD

voltage may be sourced from the internal charge

pump when VLCDEXT = 0. V5 can also be sourced externally when R03EXT
is set.

When using an external resistor divider R33 may serve as a switched-V

LCD

output when VLCDEXT = 0. This allows the power to the resistor ladder to be
turned off eliminating current consumption when the LCD is not used. When
VLCDEXT = 1, R33 serves as a V

LCD

input.

Figure 19−3. Bias Generation

0

1

VLCDEXT

0

0

LCD Off

Internal VLCD

LCDREF/R13

R23

R03

LCDCAP/R33

REXT

1

0

1

0

1

0

1

0

V5

V4 int.

V3 int.

V2 int.

VLCD

AVCC

LCD2B

0

VLCDx > 0
VLCDREFx > 0

R03EXT

Charge

Pump

DVCC

R

R

R

R

R

Rx

Rx

Rx

Static

1/2 Bias 1/3 Bias

Optional External Resistors

Rx = Optional Contrast Control

V1 (V

LCD

)

V2 (2/3 V

LCD

)

V3 (1/2 V

LCD

)

V4 (1/3 V

LCD

)

Advertising