Texas Instruments MSP430x4xx User Manual

Page 398

Advertising
background image

ADC12 Registers

20-22

ADC12

MSC

Bit 7

Multiple sample and conversion. Valid only for sequence or repeated modes.
0

The sampling timer requires a rising edge of the SHI signal to trigger
each sample-and-conversion.

1

The first rising edge of the SHI signal triggers the sampling timer, but
further sample-and-conversions are performed automatically as soon
as the prior conversion is completed.

REF2_5V

Bit 6

Reference generator voltage. REFON must also be set.
0

1.5 V

1

2.5 V

REFON

Bit 5

Reference generator on
0

Reference off

1

Reference on

ADC12ON

Bit 4

ADC12 on
0

ADC12 off

1

ADC12 on

ADC12OVIE

Bit 3

ADC12MEMx overflow-interrupt enable. The GIE bit must also be set to
enable the interrupt.
0

Overflow interrupt disabled

1

Overflow interrupt enabled

ADC12
TOVIE

Bit 2

ADC12 conversion-time-overflow interrupt enable. The GIE bit must also be
set to enable the interrupt.
0

Conversion time overflow interrupt disabled

1

Conversion time overflow interrupt enabled

ENC

Bit 1

Enable conversion
0

ADC12 disabled

1

ADC12 enabled

ADC12SC

Bit

0

Start conversion. Software-controlled sample-and-conversion start.
ADC12SC and ENC may be set together with one instruction. ADC12SC is
reset automatically.
0

No sample-and-conversion-start

1

Start sample-and-conversion

Advertising