background image

Timer_A Registers

12-22

Timer_A

TACCTLx, Capture/Compare Control Register

15

14

13

12

11

10

9

8

CMx

CCISx

SCS

SCCI

Unused

CAP

rw−(0)

rw−(0)

rw−(0)

rw−(0)

rw−(0)

r−(0)

r−(0)

rw−(0)

7

6

5

4

3

2

1

0

OUTMODx

CCIE

CCI

OUT

COV

CCIFG

rw−(0)

rw−(0)

rw−(0)

rw−(0)

r

rw−(0)

rw−(0)

rw−(0)

CMx

Bit
15-14

Capture mode
00

No capture

01

Capture on rising edge

10

Capture on falling edge

11

Capture on both rising and falling edges

CCISx

Bit
13-12

Capture/compare input select. These bits select the TACCRx input signal.
See the device-specific datasheet for specific signal connections.
00

CCIxA

01

CCIxB

10

GND

11

V

CC

SCS

Bit 11

Synchronize capture source. This bit is used to synchronize the capture input
signal with the timer clock.
0

Asynchronous capture

1

Synchronous capture

SCCI

Bit 10

Synchronized capture/compare input. The selected CCI input signal is
latched with the EQUx signal and can be read via this bit

Unused

Bit 9

Unused. Read only. Always read as 0.

CAP

Bit 8

Capture mode
0

Compare mode

1

Capture mode

OUTMODx

Bits
7-5

Output mode. Modes 2, 3, 6, and 7 are not useful for TACCR0 because EQUx
= EQU0.
000 OUT bit value
001 Set
010 Toggle/reset
011 Set/reset
100 Toggle
101 Reset
110 Toggle/set
111

Reset/set