Timer_A Operation

12-5

Timer_A

12.2.2 Starting the Timer

The timer may be started, or restarted in the following ways:

-

The timer counts when MCx > 0 and the clock source is active.

-

When the timer mode is either up or up/down, the timer may be stopped
by writing 0 to TACCR0. The timer may then be restarted by writing a
nonzero value to TACCR0. In this scenario, the timer starts incrementing
in the up direction from zero.

12.2.3 Timer Mode Control

The timer has four modes of operation as described in Table 12−1: stop, up,
continuous, and up/down. The operating mode is selected with the MCx bits.

Table 12−1.Timer Modes

MCx

Mode

Description

00

Stop

The timer is halted.

01

Up

The timer repeatedly counts from zero to the value of
TACCR0

10

Continuous

The timer repeatedly counts from zero to 0FFFFh.

11

Up/down

The timer repeatedly counts from zero up to the value of
TACCR0 and back down to zero.