Tsm test cycles, Figure 24−9. test cycle insertion – Texas Instruments MSP430x4xx User Manual

Page 478

Advertising
background image

Scan IF Operation

24-18

Scan IF

TSM Test Cycles

For calibration purposes, to detect sensor drift, or to measure signals other
than the sensor signals, a test cycle may be inserted between TSM cycles by
setting the SIFTESTD bit. The time between the TSM cycles is not altered by
the test cycle insertion as shown in Figure 24−9. At the end of the test cycle
the SIFTESTD bit is automatically cleared. The TESTDX signal is active during
the test cycle to control input and output channel selection. TESTDX is
generated after the SIFTESTD bit is set and the next TSM sequence
completes.

Figure 24−9. Test Cycle Insertion

TSM Start Signal

(Divided ACLK)

Normal Cycle

Normal

Cycle

Test

Cycle

Normal Cycle

Normal

Cycle

Test

Cycle

SIFTESTD

SIFTESTD set by Software

TSM Active

TESTDX

SIFTESTD automatically cleared